language-icon Old Web
English
Sign In

Immunostaining

In biochemistry, immunostaining is any use of an antibody-based method to detect a specific protein in a sample. The term 'immunostaining' was originally used to refer to the immunohistochemical staining of tissue sections, as first described by Albert Coons in 1941. However, immunostaining now encompasses a broad range of techniques used in histology, cell biology, and molecular biology that use antibody-based staining methods. In biochemistry, immunostaining is any use of an antibody-based method to detect a specific protein in a sample. The term 'immunostaining' was originally used to refer to the immunohistochemical staining of tissue sections, as first described by Albert Coons in 1941. However, immunostaining now encompasses a broad range of techniques used in histology, cell biology, and molecular biology that use antibody-based staining methods. Immunohistochemistry or IHC staining of tissue sections (or immunocytochemistry, which is the staining of cells), is perhaps the most commonly applied immunostaining technique. While the first cases of IHC staining used fluorescent dyes (see immunofluorescence), other non-fluorescent methods using enzymes such as peroxidase (see immunoperoxidase staining) and alkaline phosphatase are now used. These enzymes are capable of catalysing reactions that give a coloured product that is easily detectable by light microscopy. Alternatively, radioactive elements can be used as labels, and the immunoreaction can be visualized by autoradiography. Tissue preparation or fixation is essential for the preservation of cell morphology and tissue architecture. Inappropriate or prolonged fixation may significantly diminish the antibody binding capability. Many antigens can be successfully demonstrated in formalin-fixed paraffin-embedded tissue sections. However, some antigens will not survive even moderate amounts of aldehyde fixation. Under these conditions, tissues should be rapidly fresh frozen in liquid nitrogen and cut with a cryostat. The disadvantages of frozen sections include poor morphology, poor resolution at higher magnifications, difficulty in cutting over paraffin sections, and the need for frozen storage. Alternatively, vibratome sections do not require the tissue to be processed through organic solvents or high heat, which can destroy the antigenicity, or disrupted by freeze thawing. The disadvantage of vibratome sections is that the sectioning process is slow and difficult with soft and poorly fixed tissues, and that chatter marks or vibratome lines are often apparent in the sections. The detection of many antigens can be dramatically improved by antigen retrieval methods that act by breaking some of the protein cross-links formed by fixation to uncover hidden antigenic sites. This can be accomplished by heating for varying lengths of times (heat induced epitope retrieval or HIER) or using enzyme digestion (proteolytic induced epitope retrieval or PIER). One of the main difficulties with IHC staining is overcoming specific or non-specific background. Optimisation of fixation methods and times, pre-treatment with blocking agents, incubating antibodies with high salt, and optimising post-antibody wash buffers and wash times are all important for obtaining high quality immunostaining. In addition, the presence of positive and negative controls for staining are essential for determining specificity. A flow cytometer can be used for the direct analysis of cells expressing one or more specific proteins. Cells are immunostained in solution using methods similar to those used for immunofluorescence, and then analysed by flow cytometry. Flow cytometry has several advantages over IHC including: the ability to define distinct cell populations by their size and granularity; the capacity to gate out dead cells; improved sensitivity; and multi-colour analysis to measure several antigens simultaneously. However, flow cytometry can be less effective at detecting extremely rare cell populations, and there is a loss of architectural relationships in the absence of a tissue section. Flow cytometry also has a high capital cost associated with the purchase of a flow cytometer. Western blotting allows the detection of specific proteins from extracts made from cells or tissues, before or after any purification steps. Proteins are generally separated by size using gel electrophoresis before being transferred to a synthetic membrane via dry, semi-dry, or wet blotting methods. The membrane can then be probed using antibodies using methods similar to immunohistochemistry, but without a need for fixation. Detection is typically performed using peroxidase linked antibodies to catalyse a chemiluminescent reaction. Western blotting is a routine molecular biology method that can be used to semi-quantitatively compare protein levels between extracts. The size separation prior to blotting allows the protein molecular weight to be gauged as compared with known molecular weight markers.

[ "Immunohistochemistry", "Cell", "Canalicular Pattern", "Cytokeratin AE1+AE3", "GYIRFamide", "Pimonidazole Hydrochloride", "MIB-1 antibody" ]
Parent Topic
Child Topic
    No Parent Topic