Direct coombs test

A Coombs test (also known as antiglobulin test or AGT) is either of two clinical blood tests used in immunohematology and immunology. The two Coombs tests are the direct Coombs test (DCT, also known as direct antiglobulin test or DAT), and the indirect Coombs test (also known as indirect antiglobulin test or IAT). The direct Coombs test detects antibodies that are stuck to the surface of the red blood cells. Since these antibodies sometimes destroy red blood cells, a person can be anemic and this test can help clarify the condition. The indirect Coombs detects antibodies that are floating freely in the blood. These antibiodies could act against certain red blood cells and the test can be done if you have had a blood transfusion and might be having a reaction to the blood.The two Coombs tests are based on anti-human antibodies binding to human antibodies, commonly IgG or IgM. These anti-human antibodies are produced by plasma cells of non-human animals after immunizing them with human serum. Additionally, these anti-human antibodies will also bind to human antibodies that may be fixed onto antigens on the surface of red blood cells (RBCs). In the appropriate test tube conditions, this can lead to agglutination of RBCs and allowing for visualisation of the resulting clumps of RBCs. If clumping is seen, the Coombs test is positive; if not, the Coombs test is negative.The direct Coombs test (also known as the direct antiglobulin test or DAT) is used to detect if antibodies or complement system factors have bound to RBCs surface antigens in vivo. The DAT is not currently required for pre-transfusion testing but may be included by some laboratories.The indirect Coombs test (also known as the indirect antiglobulin test or IAT) is used to detect in-vitro antibody-antigen reactions. It is used to detect very low concentrations of antibodies present in a patient's plasma/serum prior to a blood transfusion. In antenatal care, the IAT is used to screen pregnant women for antibodies that may cause hemolytic disease of the newborn. The IAT can also be used for compatibility testing, antibody identification, RBC phenotyping, and titration studies.Coombs reagent (also known as Coombs antiglobulin or antihuman globulin) is used in both the direct Coombs test and the indirect Coombs test. Coombs reagent is antihuman globulin. It is made by injecting human globulin into animals, which produce polyclonal antibodies specific for human immunoglobulins and human complement system factors. More specific Coombs reagents or monoclonal antibodies can be used.Both IgM and IgG antibodies bind strongly with their complementary antigens. IgG antibodies are most reactive at 37 °C. IgM antibodies are easily detected in saline at room temperature as IgM antibodies are able to bridge between RBC’s owing to their large size, efficiently creating what is seen as agglutination. IgG antibodies are smaller and require assistance to bridge well enough to form a visual agglutination reaction. Reagents used to enhance IgG detection are referred to as potentiators. RBCs have a net negative charge called zeta potential which causes them to have a natural repulsion for one another. Potentiators reduce the zeta potential of RBC membranes. Common potentiators include low ionic strength solution (LISS), albumin, polyethylene glycol (PEG), and proteolytic enzymes.The Coombs test was first described in 1945 by Cambridge immunologists Robin Coombs (after whom it is named), Arthur Mourant and Rob Race. Historically, it was done in test tubes. Today, it is commonly done using microarray and gel technology.

[ "Antibody", "Diabetes mellitus", "Anemia", "Disease", "Hemolysis" ]
Parent Topic
Child Topic
    No Parent Topic