Histomorphometrische Evaluation poröser Titanprobenkörper anhand eines computergestützten Bildanalysesystems / Histomorphometric evaluation of bone ingrowth of porous titanium by a computer-assisted analyzing system
2005
: The objective of this study was to evaluate the bone ingrowth of a new vacuum plasma sprayed titanium surface (vps-ti) in comparison to cs-titanium implants in a gottinger minipig model. Fifteen gottinger minipigs each received the two implants, vacuum plasma sprayed titanium with a porosity of 50% and a pore size of 200 microm (vps-ti) and an implant with a similar porosity but a different pore size 500 microm (cs-ti), at the proximal femur metaphysis by press-fit technique. The pigs were euthanized at three different postsurgical periods: 4, 8 and 12 weeks. Each femur was harvested and qualitative (macroscopic and microscopic) and quantitative (histomorphometric) histological analysis was done on histological slides. The results indicated that there was a difference in bone ingrowth between the two implants, whereas the bone ingrowth of vps-ti was superior to cs-ti after 4 and 8 weeks healing time. 12 weeks post implantationem no statistiscal difference was evident. The pore size of 200 microm seemed superior to a pore size of 500 microm. Whether or not these effects lead to a better mechanical stability remains unanswered.
Keywords:
- Correction
- Source
- Cite
- Save
- Machine Reading By IdeaReader
14
References
2
Citations
NaN
KQI