Influence of low-temperature degradation on the wear characteristics of zirconia against polymer-infiltrated ceramic-network material

2018 
Abstract Statement of problem Low-temperature degradation may affect zirconia restorations during their clinical service. Concerns have been raised about the effect of low-temperature degradation on the wear behavior of zirconia. Moreover, the wear resistance of this novel polymer-infiltrated ceramic-network material needs to be better evaluated. Purpose The purpose of this in vitro study was to investigate the influence of aging on the wear resistance of zirconia opposing polymer-infiltrated ceramic-network material. Material and methods Twelve specimens for 2 newly developed polymer-based materials (a polymer-infiltrated ceramic-network material VITA ENAMIC and a resin nanocomposite material Lava Ultimate), 2 commonly used glass-ceramic materials (IPS e.max CAD and VITABLOCS Mark II), and 2 conventional composite resin materials (VITA CAD-Temp and PMMA Disk) were tested; human enamel was used as a control group. The wear simulator used was a ball-on-disk type with zirconia balls, with and without autoclaving (134°C, 200 kPa, 20 hours) as antagonists. The vertical loss and volume loss of specimens and the roughness average of zirconia antagonists were measured with a 3-dimensional optical profilometer. Vickers hardness values were determined using a micro-Vickers hardness tester. Data were statistically analyzed with a mixed-model ANOVA for wear loss (vertical loss [μm] and volume loss [mm 3 ]) and roughness average (μm) of zirconia antagonists and with the Kruskal-Wallis test for Vickers hardness values (α=.05). The Spearman correlation coefficient was used to determine the relationship between wear loss and hardness. Results Results showed that specimens opposing the non-aged zirconia balls demonstrated significantly higher wear than those opposing the aged ones ( P 3 ) and the resin nanocomposite material Lava Ultimate group (vertical loss=24.42-27.83 μm, volume loss=0.0159-0.0233 mm 3 ) showed lower vertical loss and volume loss than the conventional composite resin groups (vertical loss=43.95-61.87 μm, volume loss=0.0395-0.0593 mm 3 ) but higher wear than the glass-ceramic groups (IPS e.max CAD and VITABLOCS Mark II; vertical loss=8.95-11.47 μm, volume loss=0.0072-0.0094 mm 3 ) and human enamel (vertical loss=9.95-12.32 μm; volume loss=0.0089-0.0103 mm 3 ). The aged zirconia antagonists indicated greater roughness average values than the aged zirconia balls after the wear test ( P Conclusions Even though zirconia ceramic subjected to low-temperature degradation exhibited increased roughness after the wear test, it was still nonabrasive toward opposing materials. The polymer-infiltrated ceramic-network material showed intermediate wear resistance compared with glass-ceramic and conventional composite resin.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    40
    References
    10
    Citations
    NaN
    KQI
    []