The Collaborate Calibration and Alignment of Button-type BPM

2015 
Beam position monitor (BPM) can easily reinforce the handling of beam orbits and measure the absolute beam position [1]. Its data can be used to optimize and correct beam in both first turn and closed orbit mode. In order to set the absolute center position of Button-type BPM, and formulate the offset between mechanic and electronic center precisely, we mounted BPM together with solenoid on a vertical rotated test-bench when its calibration takes out, and developed transform software to calculate the offset. This paper describes the method and process of collaborate calibration: the assembly and alignment of BPM itself on the designed work-bench; the mechanic calibration of bundle BPM-Solenoid, and the alignment of mechanic to the wire center used by Laser Tracker and Portable coordinate measurement machine (CMM) jointly; the connection of coaxial cable and read-out for electronics; the electronic calibration of bundle BPM-Solenoid. Form the above four steps, the author analyses the error sources, measures and subtracts the offset values, and formulate the position calculation formula of offset. At last, the residual offset is nearly 20um.The total accuracy of calibration is 0.1mm.