Alignment Method of ECH Transmission Lines Based on the Moment and Phase Retrieval Method Using IR Images
2005
New alignment methods of millimeter-wave transmission lines for Electron Cyclotron resonance Heating are proposed and evaluated on a high power level. These methods are based on the measured data of infrared images on the target, which is irradiated by the high power millimeter-waves at several positions. The first and second moments and retrieved phase obtained from these data are used to determine the propagation direction of the millimeter-wave beam along the waveguide axis. It is demonstrated that these methods have sufficient resolution to discriminate 0.1 deg., which is required to restrict the transmission loss below 1% over the 100 GHz range.