The potential of SO2 for reducing corrosion in WtE plants

2014 
Due to the high-temperature boiler corrosion induced by chloride-rich fly ash deposits, steam generation in today’s Waste-to-Energy (WtE) plants is typically designed only for 40 bar/400 °C as an economic compromise between acceptable corrosion rate and maximum power generation. The high-corrosive metal chlorides in the fly ash can react with SO2 forming low-corrosive sulfates. The sulfation efficiency is enhanced by high SO2 levels and sufficient residence time of the flue gas at high-temperatures (700–900 °C). The fly ash sulfation was tested in full scale in a Swedish WtE plant by applying the economic sulfur recirculation method. Probes of several alloys (16Mo3, Inconel 625, Sanicro 28) were exposed for 1000 h at controlled material temperatures in the superheater position, at normal and during sulfating operation respectively. Analyses of the fly ash showed that the molar Cl/S was decreased to values well below 1 and the corresponding corrosion rates of the individual material samples were less than half when sulfur recirculation was in operation. These positive findings demonstrate that the sulfur recirculation process has high potential for low-corrosive high-temperature steam generation (T ≈ 500 °C) and improved electricity production. Further steam superheating can be realized by staged superheating using small amounts of secondary fuel.