Optimization of Multiple Jet Arrays for Helium-Cooled Finger-Type Divertors

2017 
AbstractThe leading candidate for the DEMO divertor is the helium-cooled modular divertor with multiple jets (HEMJ) design, which is to date the only design that has been experimentally shown to accommodate incident steady-state heat fluxes greater than 10 MW/m2. In the HEMJ, the divertor target plates are cooled by 25 jets of different diameters that impinge upon a curved tungsten (W)-alloy surface brazed to a hexagonal W tile. Given the difficulties in manufacturing such a complicated geometry in W and W-alloys, numerical simulations were performed to determine if simplified versions of the HEMJ design could provide similar thermal-hydraulic performance. Parametric studies were performed at fully prototypical conditions using one-way coupled thermo-mechanical and fluid dynamics simulations in ANSYS® Workbench® to determine the effect of varying the jet-to-cooled surface distance, the number, diameter, and spacing of the jet holes (the jets were all assumed to have the same diameter), and the curvature o...
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    7
    References
    6
    Citations
    NaN
    KQI
    []