Antiangiogenic Human Monoclonal Antibody Ramucirumab Radiolabelling: In Vitro Evaluation on VEGFR2-positive Cell Lines

2019 
: Background/Aim: Radiolabelling of monoclonal antibodies (mAbs) could be beneficial in cancer diagnosis and therapy, however it may cause structural changes and consequently deteriorate their immunoreactivity. Materials and Methods: The therapeutic mAb ramucirumab (RAM) was technetium-99m labelled using either a direct or an indirect method with the use of two bifunctional chelating agents (HYNIC, DTPA). The radiochemical purity was assessed using instant thin-layer chromatography (ITLC) and high-performance liquid chromatography (HPLC) technique. The affinity of radiolabelled RAM was tested on human cancer cell lines. Results: The radiolabelling provided the following stable compounds: [99mTc]RAM, [99mTc]HYNIC-RAM and [99mTc]DTPA-RAM. Their radiochemical purity was over 95%. All prepared radiopharmaceuticals showed moderate affinity to the targeted receptor, in vitro. However, their affinity was one order lower compared to that of the natural mAb. Moreover, directly and DTPA-radiolabelled RAM demonstrated less favourable binding kinetics. Conclusion: Radiolabelling negatively affected the affinity of RAM to its targeted receptor.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    0
    References
    2
    Citations
    NaN
    KQI
    []