Managing radiation degradation of CCDs on the Chandra X-ray Observatory III
2005
Soon after the start of science operations of the Chandra X-ray Observatory , it became apparent that weakly penetrating
(0.1-0.5 MeV) protons in the Earth's radiation belt were causing an unexpectedly rapid increase in the charge-transfer
inefficiency of Chandra's front-illuminated CCDs. Fortunately, the Chandra team developed, implemented, and
maintains a radiation-protection program that successfully reduced the rate of degradation of the CCDs' performance to
acceptable levels. Since implementing this program, the average rate of increase of the charge-transfer inefficiency has
slowed to 3.2×10 -6 /y (2.3%/y) for the front-illuminated CCDs and 1.0×10 -6 /y (5.8%/y) for the back-illuminated CCDs.
This paper reviews the Chandra radiation-management program, reports the current status, and describes changes
planned or implemented since the previous paper on this topic.