A Study on the Strong Duality of Second-Order Conic Relaxation of AC Optimal Power Flow in Radial Networks

2021 
For the popular second-order conic program (SOCP) formulation of AC optimal power flow (OPF) in a radial network, this paper first shows that it does not have the strong duality property in general. Then, through a series of restrictive reformulations, we derive a set of closed-form sufficient conditions on network parameters that ensure its strong duality. Numerical studies on IEEE 33-bus, 69-bus test networks and two real-world distribution systems confirm that non-negligible duality gaps do exist in this SOCP formulation, and also demonstrate the validity of proposed sufficient conditions on closing the duality gap. Our results provide an analytical tool to ensure strong duality of the SOCP power flow formulation and to support algorithm developments for its complex extensions.