1 kV Wideband Voltage Transducer, a Novel Method for Calibration and a Voltage Measurement Chain

2019 
A new reference resistive-capacitive voltage divider is presented in this paper, operating in dc and ac from 10 to 200 kHz. The ratio error is lower than 0.1% and the phase error is lower than $400~\mu $ rad (1.375’) at 100 kHz. The divider is stable and repeatable. The scale factor (SF) and the phase error repeatability, tested in 24-h continuous measurements repeated during 15 weeks, show an SF variation lower than 80 ppm and a phase error variation lower than 20 $\mu $ rad. This allows one to define a calibration matrix of the device bringing its relative measurement uncertainty lower than $0.5 \cdot 10^{-3}$ . The divider calibration has been obtained with a step-up method, which could improve traceability in many laboratories and is described in this paper. The divider can be embedded in a calibration chain to test the accuracy of voltage transducers in the measurement of the ac voltage ripple, in the presence of a significant dc component, as it occurs in many power electronic systems. The voltage calibration chain is based on the use of the reference divider and a voltage injector, the secondary of which is placed in series with a stable dc source. By means of this calibration system, one of the best commercial voltage transducers on the market has been analyzed. This paper also highlights how the proposed voltage calibration chain could be used in perspective in a phantom power system for the development of a dc plus ac power standard.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    12
    References
    7
    Citations
    NaN