The FILTEX / HERMES polarized hydrogen atomic beam source

1994 
Abstract The FILTEX/HERMES atomic beam source (ABS) for polarized hydrogen is described. Recent improvements concern mainly the optimization of the beam forming system and a new design of the sextupole magnet system. For a precise measurement (error 5%) of the output flow a calibrated compression tube was installed. The output flow of 0.81×10 17 H atoms per second in two hyperfine substates was constant within 2% in a long-term measurement over 16 h. At the FILTEX test experiment, the target density in the storage cell fed by the ABS was constant within the experimental error of 4% over a period of four months.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    8
    References
    42
    Citations
    NaN
    KQI
    []