Flatcoil systems for measurements of Fermilab magnets

1996 
A flux measurement system has been developed for measuring the integrated strength and relative shape of the magnetic field of Fermilab Main Injector dipoles. Improved field shape measurements have been obtained by constructing coil geometries which reduce the flux contribution from unwanted field derivatives. A bucking coil scheme employing reference coils in both the test magnet and a reference magnet reduce the sensitivity to power supply fluctuations. Design strategies for various measurement requirements are described, along with the details of implementing an assembly to measure curved 6 m and 4 m dipoles. Some representative results and comparison with redundant measurement systems are presented.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    5
    References
    3
    Citations
    NaN
    KQI
    []