Viscosity of Al-Cu liquid alloys - Measurement and thermodynamic description

2012 
In the present work a high temperature oscillating cup viscometer has been used to measure the viscosities of liquid binary Al–Cu alloys. The dependence of viscosity on temperature is well described by the Arrhenius law. For constant temperature, the viscosity as a function of copper concentration exhibits a maximum at a mole fraction x Cu = 0.7. This might be due to a pronounced chemical short range order in the liquid phase at this composition. As the comparison of existing phenomenological models describing viscosity as a function of composition to the experimental data is unsatisfactory, a new model for the viscosity has been developed within this work based only on a few assumptions and using the enthalpy of mixing as input parameter which is easily accessible. The agreement between model calculation and experimental data is excellent.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    31
    References
    53
    Citations
    NaN
    KQI
    []