Benchmark validation comparisons of measured and calculated delayed neutron detector responses for a pulsed photonuclear assessment technique

2007 
An MCNPX-based calculational methodology has been developed to numerically simulate the complex electron–photon–neutron transport problem for the active interrogation system known as the pulsed photonuclear assessment (PPA) technique. The PPA technique uses a pulsed electron accelerator to generate bremsstrahlung photons in order to fission nuclear materials. Delayed neutron radiation is then detected with helium-3 neutron detectors as evidence of the nuclear material presence. Two experimental tests were designed, setup and run to generate experimental data for benchmarking purposes. The first test irradiated depleted uranium in air, and the second test, depleted uranium in a simulated cargo container (plywood pallet), using 10 MeV electron pulses. Time-integrated, post-flash, delayed neutron counts were measured and compared to calculated count predictions in order to benchmark the calculational methodology and computer models. Comparisons between the experimental measurements and numerical predictions of the delayed neutron detector responses resulted in reasonable experiment/calculated ratios of 1.42 and 1.06 for the two tests. High-enriched uranium (HEU) predictions were also made with the benchmarked models.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    2
    References
    5
    Citations
    NaN
    KQI
    []