PSR electron cloud detector and suppressor mechanical design and fabrication

2007 
In order to better understand the two stream e-p instability issue in the LANSCE Proton Storage Ring (PSR), a new diagnostic instrument has been developed to measure the electron cloud formation and trapping in a quadrupole magnet at the LANSCE PSR. The device called the Electron Cloud Detector (ECD) was fabricated and has successfully been installed in the PSR. Along with the Electron Cloud Detector, an additional device was developed to manipulate electrons ejected from the quadrupole and allow additional information to be obtained from ECD measurements. This paper will discuss the mechanical design and fabrication issues encountered during the course of developing both devices.