RP-HPLC Method for the Estimation of Atorvastatin Calcium in Bulk and Pharmaceutical Formulations

2011 
The present work describes a simple reverse phase HPLC method for the estimation of Atorvastatin calcium in bulk and pharmaceutical formulations. The estimation was carried out on phenomenex C18 (250 × 4.6 mm, 5μ) column using a mobile phase containing of Acetonitrile: Ortho-phosphoric acid (0.1%): Tetrahydrofuran (48:0.04:52). The eluent was monitored at 244 nm. The results have been validated statistically and recovery studies confirmed the accuracy of proposed method.