Machining accuracy improvement for a dual-spindle ultra-precision drum roll lathe based on geometric error analysis and calibration

2020 
Abstract This paper performs a comprehensive analysis and calibration on the geometric error of the ultra-precision drum roll lathe with dual-spindle symmetrical structure and cross slider layout. Firstly, the volumetric error model which contains all geometric errors of the dual-spindle ultra-precision drum roll lathe (DSUPDRL) is developed based on the combination of the homogenous transfer matrix (HTM) and multi-body system (MBS) theory. Secondly, sensitivity analysis for the volumetric error model is conducted to identify the sensitive geometric error components of the DSUPDRL using an improved Sobol method based on the quasi-Monte Carlo algorithm. The result of sensitivity analysis laid the foundation for the subsequent geometric error calibration. Then, some sensitive error components along the X and Z directions are calibrated using a laser interferometer and a pair of inductance displacement probes. Besides the volumetric error model, the concentricity error caused by dual-spindle symmetrical structure is proposed and calibrated by the on-machine measurement using a classic reversal method. Finally, a large-scale roller mold with a diameter of 250 mm and a length of 600 mm is machined using the DSUPDRL after calibration. The experimental result shows that 1.4 μm/600 mm generatrix accuracy is obtained, which validate the effectiveness of the geometric error analysis and calibration.