[LC-MS/MS Determination of Tenofovir in Human Plasma and Its Bioequivalence].
2018
OBJECTIVE:To develop a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for detecting tenofovir in human plasma. METHODS:Twenty four healthy male volunteers received a single oral dose of 300 mg tenofovir disoproxil fumarate tablets under fasting and high-fat diet conditions in a randomized four-way crossover bioequivalence study with two preparations of tablets. Plasma samples were taken and analyzed using the LC-MS/MS method. The pharmacokinetic parameters of the two preparations were calculated and compared statistically to evaluate their bioequivalence using Phoenix Winnonlin6.3. RESULTS:Linear detection responses were obtained for tenofovir at the range from 3.13 to 500 ng/mL. The intra- and inter-day precisions were high,with lower than 5.43% [relative standard deviation (RSD)%],high recovery and good stability. The 90% confidence intervals of peak concentration (Cmax) of tenofovir and its area under the curve (AUC0-t and AUC0-∞ ) all fell within the bioequivalence limit 80.00%-125.00% under both fasting and high-fat diet conditions. No significant difference in peak time (Tmax) was demonstrated between the two preparations (P>0.05) . CONCLUSION:The LC-MS/MS method can be used for simultaneous determination of tenofovir in human plasma. The two preparations of tablets are bioequivalent.
Keywords:
- Correction
- Source
- Cite
- Save
- Machine Reading By IdeaReader
0
References
0
Citations
NaN
KQI