Hydrogen Induced Stress Cracking of Swaged Super Duplex Stainless Subsea Components
2019
A recent subsea failure of two subsea connectors made of UNS S32760, a 25 wt% Cr super duplex stainless steel, led to an extensive root cause failure analysis. The components showed a single longit...