Effects of sand and gating architecture on the performance of foot valve lever casting components used in pump industries

2021 
Abstract This work addresses manufacture, testing and simulation of foot valve lever (FVL) for monoblock pump industry, using a cost-effective casting design process. The impact of different types of sands, such as air-set, dry and sodium silicate as well as gating designs, namely H-, U- and O-type, were studied with respect to surface roughness and porosity. The mold pattern was produced using additive manufacturing (AM) technology. Both experimental and numerical investigations were performed on the temperature distribution of molten metal at random locations for the different gating configurations or designs, considering mold filling and solidification. It was evident from the experimental investigation that contribution of air-set sand and O-type gating architecture showed limited consistency effects. Importantly, gating architecture was the most influential parameter to determine all specified quality outcomes, independent of sand mold. An order of O