On the calibration of active binocular and RGBD vision systems for dual-arm robots

2016 
This paper describes a camera and hand-eye calibration methodology for integrating an active binocular robot head within a dual-arm robot. For this purpose, we derive the forward kinematic model of our active robot head and describe our methodology for calibrating and integrating our robot head. This rigid calibration provides a closed-form hand-to-eye solution. We then present an approach for updating dynamically camera external parameters for optimal 3D reconstruction that are the foundation for robotic tasks such as grasping and manipulating rigid and deformable objects. We show from experimental results that our robot head achieves an overall sub millimetre accuracy of less than 0.3 millimetres while recovering the 3D structure of a scene. In addition, we report a comparative study between current RGBD cameras and our active stereo head within two dual-arm robotic testbeds that demonstrates the accuracy and portability of our proposed methodology.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    19
    References
    5
    Citations
    NaN
    KQI
    []