Spherical and Aspherical RGP Lens Fitting to Epithelium and Endothelium of Rabbit's Cornea-Scanning Electron Microscopy

2006 
To investigate the comparative effect of spherical and aspherical RGP lens were worn during 3 weeks on rabbit's cornea. Four white rabbits were worn right eyes with spherical lens and 4 white rabbits were worn right eyes with aspherical RGP lens. Left eyes were served as control. The rabbits were sacrificed at 3 weeks after fitting and observed morphological changes by scanning electron microscopy and also investigate proliferation rate of the corneal epithelium with RGP wearing. After spherical RGP lens wearing, the epithet layer damaged compared to aspherical lens. The superficial cell layer strip off seriously, cell size significantly changed abnormal. Both spherical and aspherical RGP lens fitting group showed so many bacteria and back surface of lens was found like a fern shape. The aspherical RGP lens original material type was some formal than spherical lens. We thought that these pattern was significantly altered with spherical lens by prohibited transmitter oxygen from atmosphere therefore the epithelium shape was changed. This suggested wearing the aspherical lens might be less physiologic than shperical lens fitting.