Examining the reliability of ADAS-Cog change scores

2016 
ABSTRACTThe purpose of this study was to estimate and examine ways to improve the reliability of change scores on the Alzheimer’s Disease Assessment Scale, Cognitive Subtest (ADAS-Cog). The sample, provided by the Alzheimer’s Disease Neuroimaging Initiative, included individuals with Alzheimer’s disease (AD) (n = 153) and individuals with mild cognitive impairment (MCI) (n = 352). All participants were administered the ADAS-Cog at baseline and 1 year, and change scores were calculated as the difference in scores over the 1-year period. Three types of change score reliabilities were estimated using multivariate generalizability. Two methods to increase change score reliability were evaluated: reweighting the subtests of the scale and adding more subtests. Reliability of ADAS-Cog change scores over 1 year was low for both the AD sample (ranging from .53 to .64) and the MCI sample (.39 to .61). Reweighting the change scores from the AD sample improved reliability (.68 to .76), but lengthening provided no use...