Numerical study of a gas coupled VM-PT hybrid cryocooler using 3He as the working fluid

2017 
The two-stage Vuilleumier gas-coupling pulse tube cryocooler (VM-PT) is one kind of novel low-frequency cryocoolers. In this gas-coupled form, the single stage Vuilleumier cryocooler serves as both pressure wave generator and a pre-cooler for coaxial pulse tube. Compared with the most commercialized GM and GM pulse tube cryocooler, the two-stage VM-PT cryocooler is characterized by its high stability, compact size and thermal actuation which are indispensable for space application. It has already been verified experimentally that this cryocooler can obtain 9.75mW@4.2K and the lowest no-load temperature 3.39K when 4He as the working fluid. However, such refrigerating capacity seems not enough for further application. 3He as a more potential substitution of 4He has better physical properties to improve performance, which has been studied in GM type and Stirling pulse tube cryocooler. For further optimization, a numerical study on the specific performance of two-stage VM-PT cryocooler using 3He is carried out in the present paper though Sage software. Working at the frequency of 1.0Hz and the pressure of 0.8MPa, the two-stage VM-PT cryocooler with 3He obtained 50mW@4.06K. The usage of 3He was 0.0038kg, about 30L under STP. At 4.2K, using 3He can obtain 58mW cooling power and 0.49% relative Carnot efficiency, about 1.6 times higher than using 4He.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    17
    References
    0
    Citations
    NaN
    KQI
    []