Comparative assessment of condensation models for horizontal tubes

1999 
The condensation in horizontal tubes plays an important role e. g. for the determination of the operation mode of horizontal steam generators of VVER reactors or passive safety systems for the next generation of nuclear power plants. Two different approaches (HOTKON and KONWAR) for modeling this process have been undertaken by Forschungszentrum Julich (FZJ) and University for Applied Sciences Zittau/Gorlitz (HTWS) and implemented into the ID-thermohydraulic code ATHLET, which is developed by the Gesellschaft fur Anlagen- und Reaktorsicherheit (GRS) mbH for the analysis of anticipated and abnormal transients in light water reactors. Although the improvements of the condensation models are developed for different applications (VVER steam generators - emergency condenser of the SWR1000) with strongly different operation conditions (e.g. the temperature difference over the tube wall in HORUS is up to 30 K and in NOKO up to 250 K, the heat flux density in HORUS is up to 40 kW/m 2 and in NOKO up to 1 GW/m 2 ) both models are now compared and assessed by Forschungszentrum Rossendorf FZR e.V. Therefore post test calculations of selected HORUS experiments were performed with ATHLET/KONWAR and compared to existing A THLET and A THLET/HOTKON calculations of HTWS. It can be seen that the calculations with the extension KONWAR as well as HOTKON improve significantly the agreement between computational and experimental data.