Experimental verification of the ablation pressure dependence upon the laser intensity at pulsed irradiation of metals

2016 
Experiments for verification of a functional dependence of the ablation pressure on the irradiated surface of a target upon the laser intensity in a range from 1.2 to 350 TW/cm2 have been carried out. For that, at some intensities of the laser irradiation, time intervals between the laser pulse maximum and the moment of the shock-wave front arrival to the rear surface of the target were measured, which are dependent on the ablation pressure. Two schemes of the measurements were used. At the first scheme, at higher laser intensities, the front arrival moment is determined via an electron-optical camera when the rear surface begins glowing. At the second scheme, the front arrival moment is recorded when a probe laser pulse changes the character of the reflection by the rear surface of the irradiated target. Results of measurements are in agreement with the ablation pressure dependence upon the laser pulse intensity within 20%.