High-throughput charge exchange recombination spectroscopy system on MAST

2006 
A major upgrade to the charge exchange recombination spectroscopy system on MAST has recently been implemented. The new system consists of a high-throughput spectrometer coupled to a total of 224 spatial channels, including toroidal and poloidal views of both neutral heating beams on MAST. Radial resolution is ∼1cm, comparable to the ion Larmor radius. The toroidal views are configured with 64 channels per beam, while the poloidal views have 32 channels per beam. Background channels for both poloidal and toroidal views are also provided. A large transmission grating is at the heart of the new spectrometer, with high quality single lens reflex lenses providing excellent imaging performance and permitting the full exploitation of the available etendue of the camera sensor. The charge-coupled device camera chosen has four-tap readout at a maximum aggregate speed of 8.8MHz, and it is capable of reading out the full set of 224 channels in less than 4ms. The system normally operates at 529nm, viewing the C5+ em...