Microstructure Evolution of Hydrogenated Ti6Al4V Alloy during Compression
2012
Compression tests of the hydrogenated Ti6Al4V0.2H alloy were carried out using an Instron 5569 machine at room temperature. True stress-strain curves of the hydrogenated Ti6Al4V0.2H alloy under different compressive strains were obtained. Microstructure evolution of the hydrogenated Ti6Al4V0.2H alloy during the process of compression was investigated by optical microscopy and transmission electron microscopy. Results show that true stress-true strain curves of Ti6Al4V0.2H alloy have good repeatability. The deformation of grains, the dislocation density and slipping evolution during the process of compression are discussed.