Peculiarities of the distribution of impurities in the TGM-96 drum boilers at the TETs-23 cogeneration station under steady and transient operating conditions

2006 
We present the results from retrofitting the scheme for staged evaporation in the TGM-96 drum boilers at OAO Mosenergo’s TETs-23 cogeneration station using the technology of external cyclones for improving the quality indicators of boiler water. We also propose a computer program for calculating the distribution of impurities in boiler water, the overflow of water between compartments, and the concentration of impurities in each compartment.