Small-Scale Safety Testing of Ammonium Nitrate and Mixtures

2016 
Ammonium nitrate (AN), gunpowder (GP), and an ammonium nitrate gunpowder mixture (AN/GP) were studied for impact sensitivity by four laboratories using the drop hammer apparatus. Bruceton and Neyer methods were used as experimental protocols and for data reduction. The results are presented as 50 % probability of reaction (DH50). For AN, the DH50 values are widely varied among the participants, from sensitive to completely insensitive (limit of the equipment), with no real correlation among results. GP and the AN/GP mixture exhibited much more sensitivity overall and were in some cases within statistical values extrapolated from previous studies of RDX. The variability in results for the AN data is attributed to the difficulty in determining a positive reaction event for AN, as detailed by Neyer experiments and photography during positive reactions. Variability in results for the GP and AN/GP mixtures is attributed to equipment environment and detection criteria. This work was performed by the Integrated Data Collection Analysis (IDCA) program, a multi-laboratory effort to standardize safety testing of improvised or homemade explosives funded by the Department of Homeland Security.