Experimental and Numerical Assessment of Water Leakages in a PVC-A Pipe

2020 
Nowadays, in the definition of effective approaches for the sustainable management of water pressurized systems, the assessment of water leakages in water supply and distribution systems represents a key aspect. Indeed, the large water volumes dispersed yearly provoke relevant environmental, technical and socio-economic costs. Worldwide, many water systems show alarming levels of water losses, due to both the poor sealing of joints and the presence of cracks, enhanced by a high pressure level greater than that strictly required for assuring a proper service level to users. With the aim of analysing the correlation between pressure and leakages, in this work the results of an experimental and a numerical Computational Fluid Dynamics (CFD) investigation are provided and discussed. With reference to a drilled PVC-A (Polyvinyl Chloride-Alloy) pipe, a new-generation plastic material for water systems use, an experimental investigation was first carried out at the Laboratory of Hydraulics of the University of Naples Federico II, aimed at assessing the leakage-pressure relation for transversal rectangular orifices. A CFD model was then implemented and calibrated with experimental results, to different geometric configurations of the orifice, with the aim of assessing the dependence of the orifice geometry and orientation on the calibration of leakage law parameters.