Chemiluminescence response of Murine Macrophages on Multilayer Microfluidic Chips

2012 
We have demonstrated an integrated platform for microfluidics and chemiluminescence (CL) detection that is capable of parallel cell culture, convenient liquid manipulation, and sensitive chemiluminescent detection. Luminol-dependent CL responses induced by three different stimuli, phytohemagglutinin (PHA), concanavalin A (ConA), and lipopolysaccharides (LPS), which can evoke a CL response in macrophages, were evaluated on this microfluidic chip. We studied the dose-dependent effect of these three stimuli on CL response in murine macrophages. PHA produced the highest CL response compared to LPS and ConA. The CL intensity produced by PHA was 6.85 and four times higher than that by LPS and ConA, respectively, at the low concentration of 100 μg/ml. We have found microfluidic based CL to be a very useful screening tool, which is less laborious and more sensitive. This microfluidic system is disposable and capable of rapid device prototyping; it may prove to be very useful in clinical and pharmaceutical applications.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    24
    References
    4
    Citations
    NaN
    KQI
    []