Hybrid Modular Multilevel Converter Design and Control for Variable Speed Pumped Hydro Storage Plants

2021 
Hybrid modular multilevel converter control and design for pumped hydro storage plants is presented, addressing application-specific shortcoming of conventional back-to-back half-bridge modular multilevel converter: high common-mode-voltage machine stress. Common-mode-voltage-free operation in the entire or partial frequency range is enabled by variable DC link voltage control, through introduction of minimal full-bridge submodule share in hybrid active front-end converter stage. The developed generalized converter design approach for arbitrary DC link voltage range operation and additional internal energy balancing control layers enable down-to-zero DC voltage control. The results are verified through high-fidelity switched-model simulations of 6 kV converter, with 10/6 ratio of full-bridge to half-bridge submodules in active front-end. The analyzed hybrid active front-end stage benefits from lower converter losses for equal machine operation flexibility compared to full-bridge design, while trade-off between grid-side power factor range and full-bridge submodule share is offered within the design stage. Compared to the state-of-the-art, zero-to-rated DC link voltage operation is possible at lower full-bridge submodule share (62% against 75 %), at the penalty of reduced grid-side power factor. Alternatively, operation at higher full-bridge submodule share (62% against 50% existing solution) enables grid-side reactive power support over wide speed range, without branch current overload.