7 GHz pulsed magnicon: study and new results
1997
The report presents new experimental results obtained on 7 GHz pulsed magnicon amplifier. In 1996, the following parameters were achieved: maximum output power of 46 MW, efficiency of 49%. We relate the further magnicon parameters improving with elimination of electromagnetic fields disturbing in the output cavity induced by the large coupling of holes with the loads.