Study on cathode high voltage pulse control in image intensifier
2017
This paper briefly introduces the basic working principle of auto-gating power source. Due to the presence of noise in the
circuit, the cathode pulse signal generated by the AD converter is unstable. In this paper, the circuit of the AD converter
is adjusted to improve the instability of the cathode high voltage pulse signal, especially in the case of low light and high
illumination to avoid the jitter of the pulse. The experiment was carried out. And it could guide the implementation of
this part of the circuit.