Humidity sensor using NASICON not containing phosphorus

1991 
Abstract Humidity sensors using various NASICON materials have been experimentally produced by the thick-film printing method. Among the NASICON materials, one which did not contain phosphorus shows a comparatively low resistance in low humidity. The relation between the logarithm of its resistance and relative humidity is almost linear and hysteresis free (2 MΩ-10 kΩ in the range 20–90% r.h.). Also the humidity sensor using NASICON material not containing phosphorus compared with one using usual NASICON containing phosphorus has improved long-term stability and durability in various environmental tests.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    2
    References
    14
    Citations
    NaN
    KQI
    []