Multiscale orthogonal matching pursuit algorithm combined with peak model for interpreting ion mobility spectra and achieving quantitative analysis

2020 
Abstract Ion mobility spectrometry is an important rapid analysis method. However, it is difficult to achieve quantitative analysis when spectral peaks overlap. A new method for analyzing ion mobility spectra is presented here. The method achieves quantitative analysis by combining the advantages of the peak model(in terms of optimal physical and chemical interpretation of the system of interest) and the multiscale orthogonal matching pursuit algorithm(in terms of extracting characteristic peaks). A simulated data set, constructed using the peak model, containing overlapping peaks was analyzed to demonstrate the ability of the multiscale orthogonal matching pursuit algorithm to decompose overlapping peaks. Real data sets for methyl salicylate and a mixture of acetone and methyl salicylate at sixteen concentrations were generated using a vapor generator(using permeation tubes). The characteristic peaks were extracted using the multiscale orthogonal matching pursuit algorithm. Univariate calibrations using the peak area and peak height were prepared to allow quantitative analyses to be performed. Multivariate calibrations using partial-least-squares and poly-partial-least-squares were prepared and the results were compared with the univariate calibration results. Markedly better or similar predictions were made using the univariate calibration models involving physical and chemical interpretations than using the multivariate calibration models.