Determination of metoclopramide in human plasma by LC–ESI-MS and its application to bioequivalance studies

2010 
Abstract An LC–MS method for the determination of metoclopramide in human plasma was developed and validated. Sample preparation involved extraction with ethyl acetate. Chromatographic separation was performed on a Thermo Hypersil-Hypurity C 18 (150 mm × 2.1 mm, 5 μm) with the mobile phase consisting of 40 mM ammonium acetate–methanol–acetonitrile. A single-quadrupole mass spectrometer with an electrospray interface was operated in the selected-ion monitoring mode to detect the [M+H] + ions at m / z 300 for metoclopramide and at m / z 384 for the internal standard (prazosin). The method was validated over 0.78–50.00 ng mL −1 for metoclopramide. The recovery was 67.8–83.1%, and the limit of quantitation (LOQ) detection was 0.78 ng mL −1 for metoclopramide. The intra- and inter-day precision of the method at three concentrations was 5.0–13.6% with accuracy of 99.2–104.0%. Stability of compounds was established in a battery of stability studies. The method was successfully applied to bioequivalence studies of metoclopramide hydrochloride tablets to obtain the pharmacokinetic parameters.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    19
    References
    15
    Citations
    NaN
    KQI
    []