The Analysis of Wire Bonding Reliability under Critical Operating Conditions

2020 
This study deals with properties of the wire bond connection under critical operating conditions. Changes in electrical resistivity and mechanical strength of the connection were analyzed. In this case, critical conditions are high ambient temperature and a high current flowing through the wire bond. It was found that there is an insignificant change in electrical resistivity of a 17,5 $\mu m$ and 25,4 $\mu \mathrm{m}$ thick golden wire that was welded on thick golden film layer. However, a significant change was found in mechanical strength. The idea of an experiment is based on an assumption that this effect depends on the structure of the bonding pad and structural change of the golden wire.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    0
    References
    0
    Citations
    NaN
    KQI
    []