PMT signal increase using a wavelength shifting paint

2015 
Abstract We report a 1.65 times increase of the PMT signal and a simple procedure of application of a new wavelength shifting (WLS) paint for PMTs with non-UV-transparent windows. Samples of four different WLS paints, made from hydrocarbon polymers and organic fluors, were tested on a 5-in. PMT (ET 9390KB) using Cherenkov radiation produced in fused silica disks by 106 Ru electrons on a ‘table-top’ setup. The best performing paint was employed on two different types of 5-in. PMTs (ET 9390KB and XP4572B), installed in atmospheric pressure CO 2 gas Cherenkov detectors, and tested using GeV electrons.