Real-time mass measurement of dust particles deposited on vessel wall in a divertor simulator using quartz crystal microbalances

2015 
Abstract We are developing a dust monitoring method using quartz crystal microbalances (QCMs) equipped with a dust eliminating filter. Here we report a dust eliminating ratio of the filter and first measurement results of the QCMs in a divertor simulator. The volume of spherical dust in unit area on the filter and QCM under the filter were 2.09 × 10 −9 and 1.22 × 10 −10  m 3  m −2 , respectively. Thus, the dust eliminating ratio of the filter is 94.2%. The QCM without the filter gives deposition rate due to radicals and dust particles, whereas the QCM with the filter gives deposition rate predominantly due to radicals. From the results, we deduce information of mass fraction of dust particles in deposits.