Analysis and Study of a Bearingless AC Motor Type Divided Winding, Based on a Conventional Squirrel Cage Induction Motor

2012 
This paper shows the analysis and study of a bearingless ac Motor type divided winding for a conventional squirrel cage induction motor, (IM). The conventional IM is used as a bearingless motor for artificial-lift oil proposes, allowing a reduction in maintenance and operation costs. The goal of this paper is improving electromagnetic forces performance, such as the Lorentz and Maxwell forces, allowing rotor positioning at the rotation axis. It was used a simulator based on the finite element method for acquiring load results for a 3,75 kW, 380 V, 4-poles, 60 Hz, 1.04 Nm, IM motor. Experimental results show that is possible to use a conventional IM as a bearingless motor, achieving a 80% efficiency. This paper presents simulated and experimental results that demonstrated the operation of the IM bearingless-type split coil built from a conventional induction motor.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    9
    References
    26
    Citations
    NaN
    KQI
    []