An international comparison of mass fraction purity assignment of theophylline: CCQM Pilot Study CCQM-P20.e (Theophylline)

2009 
Under the auspices of the Organic Analysis Working Group (OAWG) of the Comit? Consultatif pour la Quantit? de Mati?re (CCQM) a laboratory comparison, CCQM-P20.e, was coordinated by the Bureau International de Poids et Mesures (BIPM) in 2006/2007. Nine national measurement institutes, two expert laboratories and the BIPM participated in the comparison. Participants were required to assign the mass fraction of theophylline present as the main component in two separate study samples (CCQM-P20.e.1 and CCQM-P20.e.2). CCQM-P20.e.1 consisted of a high-purity theophylline material obtained from a commercial supplier. CCQM-P20.e.2 consisted of theophylline to which known amounts of the related structure compounds theobromine and caffeine were added in a homogenous, gravimetrically controlled fashion. For the CCQM-P20.e.2 sample it was possible to estimate gravimetric reference values both for the main component and for the two spiked impurities. In addition to assigning the mass fraction content of theophylline for both materials, participants were requested but not obliged to provide mass fraction estimates for the minor components they identified in each sample. The results reported by the study participants for the mass fraction content of theophylline in both materials showed good levels of agreement both with each other and with the gravimetric reference value assigned to the CCQM-P20.e.2 material. There was also satisfactory agreement overall, albeit at higher levels of uncertainty, in the quantification data reported for the minor components present in both samples. In the few cases where a significant deviation was observed from the consensus values reported by the comparison participants or gravimetric reference values where these where available, they appeared to arise from the use of non-optimal chromatographic separation conditions. The results demonstrate the feasibility for laboratories to assign mass fraction content with associated absolute expanded uncertainties in the range 0.05% to 0.5% for solid organic compounds of high purity (mass fraction of main component >995 mg/g) and in the range 0.1% to 1% for compounds of lower purity (mass fraction of main component >980 mg/g). Main text. To reach the main text of this paper, click on Final Report. The final report has been peer-reviewed and approved for publication by the CCQM Working Group on Organic Analysis.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    0
    References
    8
    Citations
    NaN
    KQI
    []