A new diagnostic method for winding short-circuit fault for srm based on symmetrical component analysis

2018 
Winding short-circuit is one of the more common faults in switched reluctance motors (SRM). This paper takes an in-depth look at winding short-circuit. The characteristic of non-sinusoidal intermittent single phase current, fundamental components are extracted to reconstruct four phase symmetrical currents based on spectrum analysis of phase currents. The method of symmetrical component is used to calculate positive and negative sequence components of reconstructed currents, where then the ratio between positive and negative sequence component is seen as a fault feature and the diagnostic criterion is proposed. The simulation and experimental results are presented to confirm the implementation of the proposed method.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    0
    References
    10
    Citations
    NaN
    KQI
    []