Performance of the CAT-TPC based on two-dimensional readout strips
2021
A gas detector 140
$$\times$$
140
$$\times$$
140 mm
$$^3$$
in size, termed the compact active target time projection chamber (CAT-TPC), was developed in this study to measure resonant scattering associated with cluster structures in unstable nuclei. The CAT-TPC consists of an electronic field cage, double-thick gas-electron-multiplier foils, a general-purpose digital data acquisition system, and a newly developed two-dimensional strip-readout structure. The CAT-TPC was operated using a $$^4$$
He (96%) + CO
$$_2$$
(4%) gas mixture at 400 mbar. The working gas also serves as an active target for tracking charged particles. The overall performance of the CAT-TPC was evaluated using a collimated $$\alpha$$
-particle source. A time resolution of less than 20 ns and a position resolution of less than 0.2 mm were observed along the electron drift direction. Three-dimensional images of incident trajectories and scattering events can be clearly reconstructed under an angular resolution of approximately 0.45 degree.