Integration of Miniaturized Solid Phase Extraction and LC-MS/MS Detection of 3-Nitrotyrosine in Human Urine for Clinical Applications

2017 
Free 3-nitrotyrosine (3-NT) has been extensively used as a possible biomarker for oxidative stress. Increased levels of 3-NT have been reported in a wide variety of pathological conditions. However, existing methods lack the sufficient sensitivity and/or specificity necessary to measure the low endogenous level of 3-NT reliably and are too cumbersome for clinical applications. Hence, analytical improvement is urgently needed to accurately quantify the levels of 3-NT and verify the role of 3-NT in pathological conditions. This protocol presents the development of a novel liquid chromatography tandem mass spectrometry (LC-MS/MS) detection combined with a miniaturized solid phase extraction (SPE) for the rapid and accurate measurement of 3-NT in human urine as a non-invasive biomarker for oxidative stress. SPE using a 96-well plate markedly simplified the process by combining sample cleanup and analyte enrichment without tedious derivatization and evaporation steps, reducing solvent consumption, waste disposal, risk of contamination and overall processing time. The employment of 25 mM ammonium acetate (NH4OAc) at pH 9 as the SPE elution solution substantially enhanced the selectivity. Mass spectrometry signal response was improved through adjustment of the multiple reaction monitoring (MRM) transitions. Use of 0.01% HCOOH as additive on a pentafluorophenyl (PFP) column (150 mm x 2.1 mm, 3 µm) improved signal response another 2.5-fold and shortened the overall run time to 7 min. A lower limit of quantitation (LLOQ) of 10 pg/mL (0.044 nM) was achieved, representing a significant sensitivity improvement over the reported assays. This simplified, rapid, selective and sensitive method allows two plates of urine samples (n = 192) to be processed in a 24 h time-period. Considering the markedly improved analytical performance, and non-invasive and inexpensive urine sampling, the proposed assay is beneficial for pre-clinical and clinical studies.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    27
    References
    1
    Citations
    NaN
    KQI
    []