A 4-year prospective study to assess peri-implant hard and soft tissues adjacent to titanium versus gold-alloy abutments in cemented single implant crowns.

2006 
Purpose: The purpose of this prospective clinical study was to compare titanium and gold-alloy abutments when used with cemented, implant-supported single-tooth crowns. For 4 years following prosthodontic rehabilitation, these abutments were evaluated with respect to peri-implant marginal bone levels and peri-implant soft tissue parameters. Materials and Methods: During the years 1998 to 2000, 20 patients were selected from a patient population receiving treatment in the Implantology Department at the University of Padova, Italy. They all presented with single-tooth bilateral edentulous sites in the premolar/molar region with adequate bone width, similar bone height on each side, and an occlusal scheme that allowed for the establishment of identical occlusal cusp/fossa contacts on each side. Each subject received two identical implants (one in each edentulous site). One was randomly selected to be restored with a titanium abutment and a cemented implant-supported single-tooth crown, and the other was restored with a gold-alloy abutment and a cemented implant-supported single tooth crown. Data on peri-implant marginal bone levels and soft tissue parameters were collected for 4 years after abutment and crown insertion placement and analyzed to determine whether there was a significant (p< .001) difference with respect to the type of abutments (titanium vs. gold alloy) used. Results: All subjects completed the study. All 40 implants survived, resulting in a cumulative implant success rate of 100%. Statistical analysis revealed no significant differences between the two groups with respect to peri-implant marginal bone levels and soft tissue parameters. Conclusions: Within the limitations of this study, the results indicate that there was no evidence of different response with the peri-implant marginal bone and soft tissue when titanium or gold-alloy abutments were used in conjunction with the cemented, single-tooth implant restorations provided for this limited patient population. There was no evidence of different behavior of peri-implant marginal bone and of peri-implant soft tissue when titanium abutments or gold-alloy abutments were used for cemented single-tooth implant restorations in this limited patient population.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    33
    References
    55
    Citations
    NaN
    KQI
    []