Antimicrobial activity of a bioelectric dressing using an in vitro wound pathogen colony drip-flow reactor biofilm model

2016 
Objective: We performed in vitro antibiofilm testing of a silver and zinc containing microcurrent generating bioelectric dressing (BED) against clinical wound pathogens to determine its efficacy in preventing biofilm formation under low shear and continuous flow conditions, simulating wound infection environments. Method: We customised an in vitro colony drip-flow reactor (DFR) biofilm model for efficacy evaluation of BED. Each bacterial pathogen was diluted to 104CFU/ml and inoculated on the polycarbonate filter membrane as an abiotic support. BED and controls (no treatment, gauze, and blank polyester with no silver and zinc) were applied directly on the membranes where bacterial cultures were inoculated. Biofilms were continuously developed onto the membranes for 72 hours at room temperature. Biofilm formation was confirmed by crystal violet staining and microscopic observation. Through vigorous shaking and sonication, the released bacteria were serially diluted, plated, and incubated for 24 hours at 37...
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    24
    References
    6
    Citations
    NaN